Difference between revisions of "Qinno:qCape-ICOM1"
m |
(→Specifications) |
||
Line 76: | Line 76: | ||
! colspan="2" | Power Supply | ! colspan="2" | Power Supply | ||
|- | |- | ||
− | |Input Voltage Range||12V to | + | |Input Voltage Range||12V to 45V DC |
|- | |- | ||
|Maximum Current||2A for BBB and onboard CAPE Devices | |Maximum Current||2A for BBB and onboard CAPE Devices |
Revision as of 08:13, 25 August 2014
Contents
Description
The qinno iCOM extension module is a CAPE specifically designed for the Beagle Bone Black (BBB). The iCOM provides different interfaces and digital I/O for direct usage in industrial environment. The iCOM cape can be fed with a variable input voltage from 12V DC up to 45V DC. It provides a regulated 5V output voltage for power supply of the Beaglebone, and potentially other capes.
Designed and manufactured in Germany by company qinno www.qinno.de, custom specific variants can be offered.
Revision Changes
Revision A1
Initial release of qinno iCOM Cape
Software Support
- Beaglebone iCOM Cape revision A1 is supported by Angstrom release 09-2013
- Linux BSP and SW user manual can be downloaded here
File:Qinno Cape iCom LinuxBSP 1.0.0.zip
- Contact us for other Angstrom versions or other Linux distributions
- Major BeagleBone image releases can be downloaded here.
- Intermediate BeagleBone image releases can be downloaded here
Please follow the instructions here to write the image file to your SD card on a Windows machine.
Getting Started
Required Hardware setup:
- A BeagleBone iCom Cape
- A BeagleBone Black
- A 12V to 48V DC power supply
Software for the iCom Cape, as well as the detailled instructions are included in the BSP-package coming with the Cape.
Block diagram
Specifications
File:Datasheet qinno cape iCOM.pdf
Following are some specifications of the BeagleBone iCOM Cape:
General | |
---|---|
Bus Interface | Beagle Bone Black (BBB) Rev. B |
Ports | 2 x RS232; 1 x RS485 |
Digital Outputs | 4 |
Digital Inputs | 4 |
Certification | CE |
RoHS Compliant | Yes |
Communication | |
Data Signals RS232 | TxD; RxD; CTS; RTS |
RS485 | Termination switchable; signal and power isolated |
Digital I/O | |
Input Voltage Range | Up to 24V DC |
Output Voltage Range | 12V up to 45V DC |
Output on-state resistance | 200mOhm |
Output Load Current | Self limited; Nominal 0,7A; LED for each digital I/O |
Power Supply | |
Input Voltage Range | 12V to 45V DC |
Maximum Current | 2A for BBB and onboard CAPE Devices |
Additional Functions | |
Sensors | Onboard temperature Sensor |
Memory | Onboard CAPE EEPROM (256 kBit) |
Memory | Onboard user EEPROM (1024 kBit) |
RTC | Real time clock with CR2032 battery holder |
Status LED | Digital input and output |
Environment | |
Dimensions | 100.2 mm x 89.1 mm |
Operating Temperature | minus 20°C up to 70°C (except battery) |
Ambient Operating Humidity | 35% to 90% (at 5°C to 35°C) |
How to buy